Thank you for buying this energy efficient water heater. We
appreciate your condence in our products.
You should thoroughly read this manual before installation and/
or operation of this water heater. Please pay particular attention
to the important safety and operating instructions as well as the
WARNINGS and CAUTIONS.
Instruction Manual
KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE
WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS
PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.
RESIDENTIAL GAS WATER HEATERS
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
GAS MODELS POWER VENT GS675YRVIT AND GS675HRVIT
WITH HOT SURFACE IGNITION
PRINTED 1112 197218-005
500 Tennessee Waltz Parkway,
Ashland City, TN 37015
www.statewaterheaters.com
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - RESIDENTIAL GAS WATER HEATERS

1Thank you for buying this energy efficient water heater. We appreciate your condence in our products.You should thoroughly read this manual be

Page 2

10Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 5.5” (14.0 cm) from the front and

Page 3 - GENERAL SAFETY

11located in the above manner, should be provided. Each opening should have a free area of not less than one square inch per 4000 Btu/hr (5.5 cm2/kW

Page 4

12CLOSED WATER SYSTEMSWater supply systems may, because of code requirements or such conditions as high line pressure, among others, have ins

Page 5 - TABLE OF CONTENTS

13Figure 10 shows typical attachment of water piping to water heater. The water heater is equipped with 3/4 inch NPT water connections.NOTE: If using

Page 6

14GAS PIPINGMake sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column

Page 7 - TYPICAL INSTALLATION

15SEDIMENT TRAPSA sediment trap should be installed as close to the inlet of the water heater as practical at the time of water heater instal

Page 8

162. A venting system should terminate at least 3 feet above any forced air inlet located within 10 feet.3. The venting system should term

Page 9 - LOCATING THE NEW WATER HEATER

17 NOTE: This unit can be vented using only the following materials: PVC (DWV; ASTM D2665 or CSA B181.2), PVC (Sch 40, 80, 120; A

Page 10 - INSULATION BLANKETS

184. Do not plug in power cord until vent system is completely installed. The Power Vent operates on 120 Vac, therefore a grounded outlet must be wi

Page 11

19 CAUTIONLABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VER

Page 12 - WATER PIPING

2SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he

Page 13 - Water Damage Hazard

20INSTALLATION OF VENT SYSTEM, SIDEWALLWith the route of the venting system and selection of materials completed, as discussed in the section of this

Page 14 - GAS PIPING

21VENT PIPE PREPARATION1. INITIAL PREPARATION A. Make sure the solvent cement you are planning to use is designed for the specic application you

Page 15 - SEDIMENT TRAPS

22B. Deburring Use a knife, plastic pipe deburring tool, or le to remove burrs from the end of small diameter pipe. Be sure to remove all burrs fr

Page 16 - PLANNING THE VENT SYSTEM

23FOR YOUR SAFETY READ BEFORE OPERATINGWARNING: If you do not follow these instructions exactly, a re or explosion may result causing pr

Page 17 - BLOWER ASSEMBLY INSTALLATION

24The water temperature setting was factory set at the lowest temperature; Pressing the “COOLER” button decreases temperature and pressing th

Page 18 - INSTALLATION OF VENT SYSTEM

25FOR YOUR INFORMATIONSTART UP CONDITIONSSMOKE/ODORIt is not uncommon to experience a small amount of smoke and odor during the initial start-up. This

Page 19 - CAUTION

26VENTING SYSTEM INSPECTIONAt least once a year a visual inspection should be made of the venting system. You should look for:1. Obstructions which

Page 20

27ammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a re.ANODE ROD INSPECTIONEach water heater contai

Page 21 - AND CEMENT APPLICATIONS

28DRAINING AND FLUSHINGIt is recommended that the tank be drained and ushed every 6 months to remove sediment which may build up during op

Page 22

29LEAKAGE CHECKPOINTSNever use this water heater unless it is completely lled with water. To prevent damage to the tank, the tank must be lled with

Page 24 - TEMPERATURE REGULATION

30 Key No. Part Description 1 Pipe Nipple 2 Stamped Steel Burner 2 A Cast Iron Burner 3 Burner Tube (Stamped Burner) 3A Burner Tube (C

Page 25 - FOR YOUR INFORMATION

31TROUBLESHOOTING GUIDELINESTROUBLE SHOOTINGPlease check guidelines below. For your safety, water heater service should be performed only by a quali

Page 26 - PERIODIC MAINTENANCE

32# LED STATUS PROBLEM SOLUTION789Self diagnostic check has detected a problem with the gas valve driver circuit, internal microprocessor, or other in

Page 27 - ANODE ROD INSPECTION

33These guidelines should be utilized by a qualied service agent. TROUBLESHOOTING GUIDELINESTROUBLESHOOTING GUIDELINES

Page 29 - LEAKAGE CHECKPOINTS

35THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY. If the glass lined tank in this water heater should prove upon examination by the State Wat

Page 30 - REPAIR PARTS LIST

36500 Tennessee Waltz Parkway, Ashland City, TN 37015www.statewaterheaters.com

Page 32

5Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service.Abbreviations Found

Page 33

6For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling

Page 34

7(A) VENT PIPE(B) ANODE(C) HOT WATER OUTLET(D) OUTLET (120 VAC)(E) FLUE BAFFLE(F) GAS SUPPLY(G) MAIN MANUAL GAS SHUT OFF VALVE(H) GROUND JOINT

Page 35 - DISCLAIMERS

8TYPICAL INSTALLATIONFIGURE 2.MIXING VALVE USAGEThis water heater has been design certied as complying with American National Standard for water heat

Page 36 - Ashland City, TN 37015

9FACTS TO CONSIDER ABOUT THE LOCATIONCarefully choose an indoor location for the new water heater, because the placement is a very important considera