1Thank you for buying this energy efficient water heater. We appreciate your condence in our products.You should thoroughly read this manual be
10Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 5.5” (14.0 cm) from the front and
11located in the above manner, should be provided. Each opening should have a free area of not less than one square inch per 4000 Btu/hr (5.5 cm2/kW
12CLOSED WATER SYSTEMSWater supply systems may, because of code requirements or such conditions as high line pressure, among others, have ins
13Figure 10 shows typical attachment of water piping to water heater. The water heater is equipped with 3/4 inch NPT water connections.NOTE: If using
14GAS PIPINGMake sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column
15SEDIMENT TRAPSA sediment trap should be installed as close to the inlet of the water heater as practical at the time of water heater instal
162. A venting system should terminate at least 3 feet above any forced air inlet located within 10 feet.3. The venting system should term
17 NOTE: This unit can be vented using only the following materials: PVC (DWV; ASTM D2665 or CSA B181.2), PVC (Sch 40, 80, 120; A
184. Do not plug in power cord until vent system is completely installed. The Power Vent operates on 120 Vac, therefore a grounded outlet must be wi
19 CAUTIONLABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VER
2SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he
20INSTALLATION OF VENT SYSTEM, SIDEWALLWith the route of the venting system and selection of materials completed, as discussed in the section of this
21VENT PIPE PREPARATION1. INITIAL PREPARATION A. Make sure the solvent cement you are planning to use is designed for the specic application you
22B. Deburring Use a knife, plastic pipe deburring tool, or le to remove burrs from the end of small diameter pipe. Be sure to remove all burrs fr
23FOR YOUR SAFETY READ BEFORE OPERATINGWARNING: If you do not follow these instructions exactly, a re or explosion may result causing pr
24The water temperature setting was factory set at the lowest temperature; Pressing the “COOLER” button decreases temperature and pressing th
25FOR YOUR INFORMATIONSTART UP CONDITIONSSMOKE/ODORIt is not uncommon to experience a small amount of smoke and odor during the initial start-up. This
26VENTING SYSTEM INSPECTIONAt least once a year a visual inspection should be made of the venting system. You should look for:1. Obstructions which
27ammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a re.ANODE ROD INSPECTIONEach water heater contai
28DRAINING AND FLUSHINGIt is recommended that the tank be drained and ushed every 6 months to remove sediment which may build up during op
29LEAKAGE CHECKPOINTSNever use this water heater unless it is completely lled with water. To prevent damage to the tank, the tank must be lled with
3GENERAL SAFETY
30 Key No. Part Description 1 Pipe Nipple 2 Stamped Steel Burner 2 A Cast Iron Burner 3 Burner Tube (Stamped Burner) 3A Burner Tube (C
31TROUBLESHOOTING GUIDELINESTROUBLE SHOOTINGPlease check guidelines below. For your safety, water heater service should be performed only by a quali
32# LED STATUS PROBLEM SOLUTION789Self diagnostic check has detected a problem with the gas valve driver circuit, internal microprocessor, or other in
33These guidelines should be utilized by a qualied service agent. TROUBLESHOOTING GUIDELINESTROUBLESHOOTING GUIDELINES
34NOTES:
35THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY. If the glass lined tank in this water heater should prove upon examination by the State Wat
36500 Tennessee Waltz Parkway, Ashland City, TN 37015www.statewaterheaters.com
4GENERAL SAFETY
5Thank You for purchasing this water heater. Properly installed and maintained, it should give you years of trouble free service.Abbreviations Found
6For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling
7(A) VENT PIPE(B) ANODE(C) HOT WATER OUTLET(D) OUTLET (120 VAC)(E) FLUE BAFFLE(F) GAS SUPPLY(G) MAIN MANUAL GAS SHUT OFF VALVE(H) GROUND JOINT
8TYPICAL INSTALLATIONFIGURE 2.MIXING VALVE USAGEThis water heater has been design certied as complying with American National Standard for water heat
9FACTS TO CONSIDER ABOUT THE LOCATIONCarefully choose an indoor location for the new water heater, because the placement is a very important considera
Commentaires sur ces manuels